AMTA Paper Archive


Welcome to the AMTA paper archive. Select a category, publication date or search by author.

(Note: Papers will always be listed by categories.  To see ALL of the papers meeting your search criteria select the "AMTA Paper Archive" category after performing your search.)


Search AMTA Paper Archive
    
    




Sort By:  Date Added   Publication Date   Title   Author

Alignment

Experimental validation of Reference Chip Antennas for 5G Measurement Facilities at mm-Wave
A Giacomini, L Scialacqua, F Saccardi, L J Foged, E Szpindor, W Zhang, M Oliveira, P O Iversen, J M Baracco, October 2019

In this paper, the experimental validation of a micro-probe fed reference antenna targeting the upcoming 5G applications (24.25-29.5GHz band) is presented. The main purpose of these reference antennas is to serve as "gold standards" and to perform gain calibration of 5G test facilities through the substitution method. The outline of these antennas is based on a square array of four printed patches enclosed in a circular cavity. The RF input interface is a stripline-to-coplanar waveguide transition and allows for feeding the device with a micro-probe. Performance obtained by high-fidelity modeling is reported in the paper and correlated to experimental data. Interaction and unwanted coupling with the test equipment are discussed. The use of echo-reduction techniques and spatial filtering is investigated to mitigate these effects.

Improvements in the Measurement of Very Low Cross Polarization Using the Three Antenna Polarization Technique
A C Newell, P Vizcaino, D Gentle, Z Tian, , ,, October 2019

The Three-antenna polarization measurement technique is used to determine the axial ratio, tilt angle and sense of polarization of three antennas from measurements on each of three antenna pairs. The three antennas are generally nominally linearly polarized and the measurement data consists of the change in amplitude from the initial antenna orientation where they are co-polarized to the orientation where one of the antennas is rotated about its axis to the null amplitude position. The sign of the phase change is also noted and the phase change at the null position is known from theoretical calculations to be either plus or minus 90 degrees. The correct sign is determined from the sign of the phase change. For antennas with axial ratios in the range of 50 to 80 dB that will be used as near-field probes or as feeds for reflector antennas, it is imperative to measure the polarization parameters as accurately as possible. The primary source of uncertainty in the measurement is due to scattered signals in the measurement range that arise from multiple reflections between the two antennas and from the absorber on the chamber walls. For antennas with very large axial ratios, the scattered signals can be larger than the true measurement signal. These scattered signals can change the sign of the phase and produce large errors in the amplitude at the null. If the separation distance between the antennas is adjusted after rotating to the null to produce a maximum amplitude, the scattered signal is in phase with the true measurement signal. If the distance is adjusted for the minimum at the null, the scattered and true signals are out of phase. Measurements at these two positions will produce the best measurement of the phase sign and the true amplitude. But if measurements are being performed at a number of frequencies, the maximum and minimum amplitude positions will be different for each frequency, and this will complicate automated multifrequency measurements. New improvements have been developed in the details of the measurements that greatly improve the determination of the phase sign and the amplitude at the null for multiple frequency measurements and these will be described and illustrated in the following paper. With these improvements, the estimated uncertainty of a 60 dB axial ratio is on the order of 1.8 dB. A new technique has also been developed to improve the source correction of the pattern data for probes with large axial ratios that guarantees that the on-axis polarization of the pattern data will be identical to the results of the Three-antenna measurement. The probe correction processing will then produce the highest accuracy results for the polarization of the AUT.

A Robotic Near-Field Antenna Test System Relying on Non-Canonical Transformation Techniques
Daniël Janse Van Rensburg, Brett Walkenhorst, Quang Ton, John Demas, October 2019

A robotic near-field antenna measurement system allowing for acquisition over non-canonical measurement surfaces is presented. The robot consists of a six-axis robotic arm and a seventh axis rotary positioner and the created acquisition surface is parametrically reconfigurable. The near-field to far-field transformation required is also described. The success of the technique is demonstrated through measured results, compared to canonical measurement data.

Portable Laser Guided Robotic Metrology System
Peter A Slater, James M Downey, Marie T Piasecki, Bryan L Schoenholz, October 2019

This paper introduces the new Portable Laser Guided Robotic Metrology (PLGRM) system at the National Aeronautics and Space Administration's (NASA) Glenn Research Center. Previous work used industrial robots in fixed facilities to characterize antennas and required fixtures that do not lend themselves to portable applications. NASA's PLGRM system is designed for in-situ antenna measurements at a remote site. The system consists of a collaborative robot arm mounted on a vertical lift and a laser tracker, each on a mobile base. Together, they enable scanning a surface larger than the robot's reach. To accomplish this, the robot first collects all points within its reach, then the system is moved and the laser tracker is used to relocate the robot before additional points are captured. The PLGRM implementation will be discussed including how safety and planning are combined to effectively characterize antennas. Software defined triggering is a feature, for flexible integration of vector network analyzers and antenna controllers. Lastly, data will be shown to demonstrate system functionality and accuracy.

A Compressed Sampling for Spherical Near-Field Measurements
Cosme Culotta-López, Dirk Heberling, Arya Bangun, Arash Behboodi, Rudolf Mathar, November 2018

Spherical near-field measurements are regarded as the most accurate technique for the characterization of an Antenna Under Tests (AUT) radiation. The AUT's far-field radiation characteristics can be calculated from the Spherical Mode Coefficients (SMC), or spherical wave coefficients, determined from near-field data. The disadvantage of this technique is that, for the calculation of the SMC, a whole sphere containing the AUT must be Nyquist-sampled, thus directly implying a longer measurement time when only a few cuts are of interest. Due to antennas being spatially band-limited, they can be described with a finite number of SMC. Besides, the vector containing the SMC can be proved sparse under certain circumstances, e.g., if the AUT's radiation pattern presents information redundancy, such as an electrical symmetry with respect to coordinate system of the measurement. In this paper, a novel sampling strategy is proposed and is combined with compressed-sensing techniques, such as basis pursuit solvers, to retrieve the sparse SMC. The retrieved sparse SMC are then used to obtain the AUT's far-field radiation. The resulting far-field pattern is compared for both simulated and measured data. The reduced number of points needed for the presented sampling scheme is compared with classical equiangular sampling, together with the estimated acquisition time. The proposed sampling scheme improves the acquisition time with a reasonable error.

Compact Antenna Measurement Range for OTA testing of Active Antenna System Base Stations
L M Tancioni, A Jernberg, P Noren, P Iversen, A Giacomini, A Scannavini, R Braun, M Boumans, H Karlsson, , ,, November 2018

Measurement scenarios for 5G mobile communications are nowadays challenging the industry to define suitable turn-key solutions that allow Over the Air (OTA) testing of non-connectorized devices. In order to respond to the needs of an effective measurement solution, that allow measuring all the required OTA parameters at both sub6GHz and mm-Wave frequencies and that could be deployed in a very short time, the Compact Antenna Test Range (CATR) was chosen. In this paper, we will summarize the performance and the testing capabilities of a short focal-length, corner-fed CATR design, providing a 1.5 m x 1.5 m cylindrical Quiet Zone, operating from 1.7 GHz to 40 GHz and upgradeable to 110 GHz, allowing OTA measurements of Active Antenna System (AAS) Base Stations (BS), installed at Ericsson premises in Gothenburg, Sweden in 2017.

Geometric Effects on Radar Echoes from a Corner Reflector
P S P Wei, November 2018

Radar data on the complete polarimetric responses from a 4" dihedral corner reflector from 4 to 18 GHz have been collected and studied. As a function of the azimuth, the vertically suspended object may present itself to the radar as a dihedral, a flat plate, an edge, a wedge, or combinations of these. A two-dimensional method-of-moment (2-D MOM) code is used to model the perfectly electrical conducting (PEC) body, which allows us to closely simulate the radar responses and to provide insight for the data interpretation. Of particular interest are the frequency and angular dependences of the responses which yield information about the downrange separation of the dominant scattering centers, as well as their respective odd-or even-bounce nature. Use of the corner reflector as a calibration target is discussed.

Reflection-Based Inverse Scattering Image Reconstruction for Non-Destructive Testing
Jakob Helander, Johan Lundgren, Daniel Sjöberg, Christer Larsson, Torleif Martin, Mats Gustafsson, November 2018

Non-destructive testing (NDT) is a fundamental step in the production chain of aircraft structural components since it can save both money and time in product evaluation and troubleshooting. This paper presents a reflection-based imaging technique for electromagnetic (EM) testing of composite panels, with the device under test (DUT) being metal backed and both the transmitting and receiving components of the NDT system situated on the same side of the DUT. One of the key properties of the presented technique is the complete redundancy of a reference measurement, thereby making it feasible to retrieve a high quality image of the DUT with only a single measurement. Data for both a proof-of-concept DUT and an industrially manufactured composite panel is provided, and the retrieved images show the applicability of both the measurement technique and the imaging algorithms.

Some Advantages of Using Bi-directional S-Parameters in Near-Field Measurements 1
David R Novotny, Alex J Yuffa, Ronald C Wittmann, Michael H Francis, Joshua A Gordon, November 2018

The unknown-thru calibration technique is being used to achieve a system level calibration at millimeter wave frequencies (>50 GHz) on the robotic ranges at NIST. This two-port calibration requires the use of a full bi-directional measurement, instead of a traditional single-direction antenna measurement. We explored the value of the additional data acquired. We find that we can use this information to verify antenna/scan alignment, image the scattering from the positioner/facility, and perform a first order correction to the transmission data for uncertainties due to LO cable flexure.

Precision Optical Antenna Alignment System for Tracking Antennas in 6-DOF
Joshua A Gordon, David R Novotny, Michael S Allman, November 2018

We present on an all-optical spatial metrology system , the PiCMM, that aids in the alignment and tracking of antennas with accuracies on the order of 25 microns and 0.01 deg. This system speeds up millimeter-wave antenna alignment, does not require contact, and links spatial measurements to a laser tracker world coordinate frame. An automated Pixel Probe and dark-field imaging are used to directly measure the aperture geometry and its pose. These measurements are absolute in the world-frame of a laser tracker and associated coordinate metrol-ogy space of the antenna scanner. Thus, aperture geometries can be linked directly to any laser tracker target (i.e. 6DOF, 3DOF) and data such as that used to calibrate positioner kinematics. For example, the links and joints defining the Denavit-Hartenberg kinematic model of a robotic arm scanner. The new automated aspect of the system reduces alignment time to under an hour. The synergy with laser tracker targets allows for a high level of repeatability. Furthermore, antennas can be exchanged or realigned in the antenna scanner autonomously because antenna geometry and kinematic models reside in the same laser tracker coordinate metrology space.

Improved Nearfield Gain Measurement of High Gain Antennas Using Directivity and Loss Technique
Brian Park, Amanuel Haile, Paul Werntz, November 2018

Antenna gain is the product of directivity and antenna loss. Antenna gain is typically measured by comparing the antenna under test (AUT) to a standard gain horn (SGH) or direct gain measurement using a calibrated probe. This requires an accurate account of power into the AUT and SGH, the loss of all test cables and switches must be measured to obtain an accurate AUT gain. Additionally, SGH calibration uncertainty reduces the quality of the measurement. The gain measurement technique describe here exploits the near-field range capability of accurately producing the pattern of high gain antennas. The near-field range allows the full wave capture of antenna aperture fields and transformation to the far-field with high resolution. The new technique uses the directivity obtained by integrating the far-field pattern, accounts for the spill-over energy not measured by the near-field range, and uses measured network losses of the AUT. It does not require measured losses of test cables and switches. Since AUT losses are typically measured as part of antenna integration the technique reduces overall measurement burden. Accurate calculation of spill-over energy is the key to success. The technique has been shown to yield better accuracy than the typical gain calibration method for multi-beam high gain antennas.

Adjustment of the Cross-Polarization Null Position in a Single-Offset Reflector Compact Antenna Test Range
S Pivnenko, M Dirix, November 2018

A single-offset reflector compact antenna test range (CATR) is a widely used setup for the measurement of antennas in far-field conditions. It is well known that in quiet zone (QZ) of the CATR, the cross-polarized field has a deep null along the direction of the feed offset, but it rises to about-25dB to-30dB in perpendicular direction, at the edges of the QZ. In those situations, when the AUT cannot be located in the middle of the QZ, but appears shifted towards the edge of the QZ, either due to its mounting structure, or because it is mounted on a platform, the CATR cross-pol effect can be significant and not acceptable for a given application. In this paper, it is shown that the location of the cross-pol null in the QZ is directly dependent on the CATR feed polarization orientation. In particular, by changing the feed polarization within +/-1 deg, the location of the cross-pol null can be moved across the QZ to any desired place. The other characteristics of the QZ are not affected. The results of simulations and some representative measurements are included in this paper.

Optimized Compact Antenna Test Range with Short Focal Length for Measuring Large L/Ku-Band Active Antennas
A Jernberg, M Pinkasy, G Pinchuk, T Haze, R Konevky, L Shmidov, R Braun, G Baran, Pit-Radwar S A Baran@pitradwar Grzegorz, P Com, Iversen, A Giacomini, Marcel Boumans, November 2018

A new Compact Antenna Test Range (CATR) has been built, as a turnkey facility, with a cubic quiet zone (QZ) of 4.8m x 4.8m x 4.8m in the frequency range 0.9-18 GHz. The CATR has been installed in a new building with an isolated and stable foundation. The dimensions of a traditional CATR for such QZ size becomes impractical and requires a very large chamber. A new, diagonally fed, short focal length reflector has been developed to minimize the chamber size to fit the dimensions of 22 m x 14.5 m x 14.5 m.

Reference Chip Antenna for 5G Measurement Facilities at mm-Wave
A Giacomini, F Scattone, L J Foged, E Szpindor, W Zhang, P O Iversen, Jean-Marc Baracco, November 2018

In this paper, we present a chip antenna in the 27GHz band, targeting 5G measurements. This antenna can be used as reference in mm-wave measurement systems, such as the MVG µ-Lab, feeding the antenna under test through a micro-probe station. The reference antenna is employed to calibrate in gain through the substitution method. The antenna shown in this paper is an array of four patches, fed through a strip-line beam forming network. A transition strip-line to coplanar waveguide allows the antenna be fed by the micro-probe.

Near Field Reconstruction for Electromagnetic Exposure of 5G Communication Devices
Johan Lundgren, Jakob Helander, Mats Gustafsson, Daniel Sjöberg, Bo Xu, Davide Colombi, November 2018

Compliance with regulatory exposure requirements of power density for 5G systems will need accurate measurements. In this work a near field measurement technique for electromagnetic exposure of 5G communication devices is presented. The technique requires two measurements, one of a device under test and one of a small aperture as a calibration measurement. The method uses method of moments and involves reconstructing equivalent currents on a predefined surface. These currents are then used to generate and propagate the electromagnetic fields to an arbitrary plane and further compute the power density. The measurement data are obtained through a planar scan of a device under test using a probe and probe calibration using a small aperture to obtain an accurate field with absolute positioning. Measurement data is presented and compared with simulations for several distances and two antennas, operating at 28 GHz and 60 GHz. The computed power density agrees well with simulations.

Indoor Antenna Measurement Facility: Determination of the phase center position
Pierre Massaloux, Guillaume Cartesi, Philippe Berisset, November 2018

Indoor antenna measurement facilities are usually dedicated to characterize all the parameters of an antenna. In order to perform phase center position measurements, the CEA has designed a specific experimental layout to characterize this parameter with a very high accuracy. This paper describes this measurement facility and deals with technical decisions made during its design phase. Finally, we will talk about possibilities offered by this specific layout and the advantages of this layout compared to a classical antenna test-bench.

Enhanced PNF Probe Positioning in a Thermally-Uncontrolled Environment using Stable AUT Monuments
John H Wynne, Farzin Motamed, George E Mcadams, November 2018

The need for thermal stability in a test chamber is a well-established requirement to maintain the accuracy and repeatability sought for high frequency planar near-field (PNF) scanner measurements. When whole chamber thermal control is impractical or unreliable, there are few established methods for maintaining necessary precision over a wide temperature range. Often the antenna under test (AUT) itself will require a closed-loop thermal control system for maintaining stable performance due to combined effects from transmission heat dissipation and the environment. In this paper, we propose a new approach for near-field system design that leverages this AUT stability, while relaxing the requirement of strict whole chamber thermal control. Fixed reference monuments strategically placed around the AUT aperture perimeter, when measured periodically with a sensing probe on the scanner, allow for the modeling and correction of the scanner positioning errors. This process takes advantage of the assumed stability of the reference monuments and attributes all apparent monument position changes to distortions in the scanner structure. When this monument measurement process is coupled with a scanner structure that can tolerate wide thermal variations, using expansion joints and kinematic connections, a robust structural error correction model can be generated using a bilinear mapping function. Application of such a structure correction technique can achieve probe positioning performance similar to scanners that require tightly controlled environments. Preliminary results as well as a discussion on potential design variations are presented.

A Modern, Indoor Far-Field Extrapolation Range
Dale Canterbury, Corey Garner, William Dykeman, November 2018

Prior literature in the subject area of far-field antenna measurements has demonstrated an extrapolation technique to isolate and correct the errors due to near-zone proximity effects as well as multi-path range reflections, thus allowing data to be collected at distances much less than the conventionally defined far-field criteria. This paper describes a modern, indoor, far-field antenna measurement range specifically designed to support this extrapolation technique. A multi-axis positioning system featuring a mobile horn tower capable of motion along the chamber Z-axis is emphasized. High-speed RF instrumentation and advanced software control support the full automation of the extrapolation method. This contemporary approach is demonstrated, and measurement examples are provided for an X-band slotted waveguide array. The resultant far-field gain calculations are also compared to similar data extracted using near-field scanning techniques.

Resurfacing the NASA Langley Experimental Test Range Reflector
Ron Schulze, Matthew Bray, Nathanael Flores-Palomera, Chris Vandelinder, Richard Boucher, George Szatkowski, Larry Ticatach, Angelo Cavone, Matthew Ayers, Michael Draszt, John Rooks, , , ,, November 2018

An ambitious resurfacing campaign was launched in late 2017 to correct for large reflector surface distortions present at the NASA LaRC Experiment Test Range (ETR) in support of performing Europa Clipper flight High Gain Antenna (HGA) measurements at X-and Ka-band frequencies. The effort was successful as the worst case peak-to-peak amplitude ripple was reduced from 4.0-dB to 1.5-dB across the 4.1-meter quiet zone.

Uncertainty Analysis Technique for Planar Field-Probing Measurements and Quiet-Zone Simulations of a Compact Antenna Test Range
T M Gemmer, D Heberling, November 2018

The performance of a compact antenna test range is evaluated by field-probing measurements of the quiet zone. The comparison between the simulated and measured data, however, is misleading due to the finite measurement accuracy and the limited nature of the numerical model. In order to allow a comparison, the uncertainty terms of the field-probing measurements and the numerical model are identified based on the National Institute of Standards and Technology 18-term uncertainty analysis technique. The individual terms are evaluated with simulations or measurements using the equivalent-stray-signal model. Bearing the differences between the model and the actual measurements in mind, the electrical field can be estimated precisely within the overlapping region of both uncertainty budgets.